| J318 |
For 60 Hz Area
3-Phase Model |
| Output Power |
|
| Standby Output ::::::: KVA(kW) |
19.2(15.4) |
| Prime Output ::::::::::::KVA(kW) |
17.5(14) |
| Voltage - 3 phase |
220 208 |
| Voltage - single phase |
127 120 |
| Rated Amperage |
|
| Single phase - 110V A |
- |
| Single phase - 120V A |
30 x 3 |
| Single phase - 127V A |
27.5 x 3 |
| Single phase - 220V A |
20 x 3 |
| Single phase - 240V A |
- |
| 3 phase - 208V A |
48.5 |
| 3 phase - 220V A |
45.9 |
| 3 phase - 380V A |
- |
| 3 phase - 415V A |
- |
| Generator |
|
| Design |
Revolving-field, self/separated excited type AVR
generator |
| No. of poles |
2-Pole |
| Generator RPM |
3600 |
| Frequency Hz |
60 |
| Power Factor |
0.8 |
| Insulation |
Rotor coil; Class F, Stator coil; Class B |
| Type of Coupling |
Direct coupling |
| Diesel Engine |
|
| Kubota Engine Model |
D1005 |
| Design |
4-cycle Water cooled diesel engine |
| Starting system |
Electric - 12 volt DC |
| Displacement CC |
1001 |
| No. of Cylinders |
3 |
| Bore x Stroke Mm |
76 x 73.6 |
| Lubricating Oil |
API Service Class CD, CE, CF, 10W30 |
| Lubricating Oil Capacity |
4.3(4.54) |
| Coolant Capacity |
3.3(3.49) |
| Set |
|
| Fuel |
Diesel fuel No. 2 (ASTM D975) |
| Fuel Tank Capacity Liter (U.S. gal) |
79(20.87) |
| Fuel Consumption At Full Load L/h(g/h) |
5.82(2.89) |
| Fuel Consumption At Full Load L/h(g/h) |
4.8(2.38) |
| Fuel Consumption At Full Load L/h(g/h) |
3.87(1.92) |
| Continuous Operating Hours At Full Load :::::
hours |
13.5 |
| Continuous Operating Hours At Full Load :::::
hours |
16 |
| Continuous Operating Hours At Full Load:
::::: hours |
20 |
| Battery V-Ah/20Hr ::::: V-Ah/20Hr |
12V-65Ah |
| Type of Stop Solenoid |
Energized-to-Run |
| Sound LevelFull Load at 7 meter (23 feet)
::::: dB (A) |
81.0 |
| L x W x Hw/o Caster ::::: mm(inch) |
1215(47.9) |
| L x W x Hw/o Caster ::::: mm(inch) |
611(24.1) |
| L x W x Hw/o Caster ::::: mm(inch) |
922(36.3) |
| Approx. Dry Net Weightkg.(lb.) ::::: kg.(lb.) |
340(750) |
| Options |
|
| Caster x 4 |
N/A |